GD Series | MPPT Solar Inverter/Charger
Wide input voltage range (90-280VAC) · Adjustable transfer time · Up to 11kW · BMS ready
⚡ 3000W – 11000W
| Parameter / Model | GD-3024 | GD-3628 | GD-5548 | GD-6248 | GD-11048 |
|---|---|---|---|---|---|
| Input Formation | L+N+PE | ||||
| AC Input voltage | 220/230/240VAC | ||||
| Input voltage range | 90-280VAC±3V (Nor Model) 170-280VAC±3V (UPS model) | ||||
| Input frequency | 50/60Hz ±5% | ||||
| Output power | 3000W | 3600W | 5500W | 6200W | 11000W |
| Battery mode output voltage | 220/230/240VAC ±5% | ||||
| Battery mode output frequency | 50Hz or 60Hz ±1% | ||||
| Battery mode output wave | Pure sinewave | ||||
| Transfer Time (Adjustable) | 10ms for Computer Equipment, 20ms for Household Equipment | ||||
| Peak Power | 6200VA | 7200VA | 10000VA | 12400VA | 22000VA |
| Overload Ability |
Battery Mode: 21s @ 105%~150% Load 11s @ 150%~200% Load 400ms @ >200% Load |
||||
| Battery voltage | 24VDC | 48VDC | 48VDC | ||
| Battery Constant Charging Voltage (Adjustable) | 28.2VDC | 56.4VDC | 56.4VDC | ||
| Battery Float Charging Voltage (Adjustable) | 27VDC | 54VDC | 54VDC | ||
| PV Charging Method | MPPT | ||||
| Maximum PV Input | 4200W | — | 5500W | 6200W | 2*5500W |
| Solar input voltage range | 120-500VDC | 90-500VDC | |||
| Best VMP Working Range | 300-400VDC | ||||
| Maximum PV Input Voltage | 500VDC | ||||
| MAX PV Charge Current | 100A | 150A | |||
| MAX AC Charge Current | 60A | 60A | 60A | 80A | 150A |
| Display LED | Can display operating mode / load / input / output | ||||
| Interface 232 | 5PIN / Pitch 2.54mm, Baud Rate 2400 | ||||
| Expansion Slot Communication Interface |
2x5PIN / Pitch 2.54mm, Lithium Battery BMS Communication Card, WIFI 2x5PIN / Pitch 2.54mm |
||||
| Operating temperature | -10°C ~ 50°C | ||||
| Storage temperature | -15°C ~ 60°C | ||||
| Work Altitude |
No more than 1000m. If >1000m, rated power will lower. MAX 4000m. Refer to IEC62040. |
||||
| Operating Environment Humidity | 20%~95% Non Condensing | ||||
| Noise | <50dB | ||||
| Size (L*W*H) mm | 495*312*146 mm | 570*500*148 mm | |||
| Standards and Certifications | EN-IEC 60335-1, EN-IEC 60335-2-29, IEC 62109-1 | ||||
▲ MPPT solar charger with wide PV input range (120-500VDC, GD-11048 supports 90-500VDC).